Delta Access Control System (ACS)
Access Controller
Product Description
Delta ACS is the first family of access controllers designed specifically for alarm dealers or direct connection to central stations. Because it was designed with the central station in mind, Delta ACS works with software from leading central station automation providers, including Bold Technologies, DICE, GE MAS, Micro Key, and Patriot Systems.
Fully featured, flexible and easy to install, Delta ACS is the entry control solution—from a single-door retail shop to a large enterprise. With Delta ACS, alarm dealers can realize central station managed access control and provide installation and recurring support services, just like alarm/intrusion systems are installed and managed by your central station.
Today, approximately 85 percent of alarm monitoring customers do not currently have electronic access control. Delta ACS is the perfect product for alarm dealers to bring access control to their customers without installing an enduser dedicated PC, selling the customer specialized software, or training the customer in access control administration.
The opportunity starts with monitored alarm customers. An easy add-on to any monitored alarm system, providing an upgrade to access control for existing alarm customers, with management and administration that can be shared, or be exclusive to, the central station, the installing dealer, or to the end user.
For RFP responses and existing end-user accounts, Delta ACS security contractors have a great cost advantage. Any central station based proposal instantly has added value. For the security contractor, this enables and creates more end user services to offer your customer.
Key Features
Plug and Play Installation No additional software needed to implement-added modules only
- Industry-standard connections
- Connect from one to 64 access control readers to Delta ACS
- Add modules of 16 inputs and/or 12 outputs
Access Control Made Simple
- Fully featured access control system – not just a hook up to access control readers through an alarm panel
- Compatible with all industry standard access control readers
- Eliminates the need for a separate access control system
Central Station Operations Easy to Configure
- On-board installation tools
- Majority of configuration information automatically pulled from central station software
- As easy to configure as an alarm system
Designed for Central Stations
- Delta ACS is managed from the same, existing GUI that alarms are managed from
- Integrates plug and play compatibility with central station software from Bold Technologies, DICE, GE MAS, Micro Key and Patriot Systems
- Provides a single point of monitoring and management for intrusion and access control
Quick Integration
- Gets monitored site up and running in no time
- Installs similarly to an alarm system
- Easy to maintain – just call the central station
Seamless Operation
- Operators use same screens for access control, intrusion and fire alarm monitoring
- Operators see access information alongside intrusion alarms, reducing false alarms
- Uses back office for access control management, service reports, maintenance and billing history
Specification
Dimensions
- 5.8” W x 4.825” H x 1.275” D
- (147.32 mm x 122.55 mm x 32.38 mm)
Weight
- 13.6 oz (.38 kg)
Enclosure Material
- UL94 Polycarbonate
Power Supply Requirements
- 160 mA @ 12-18 VDC (with no readers connected)
- Recommended: Supervised linear power supply with battery backup, input surge protection, and AC Fail and battery low contact outputs.V2000 can supply
- 350 mA @ 12 VDC to two connected readers.
- Separate supervised DC supply with battery back-up recommended for door locking or relay activated devices or for HID MaxiProx readers.
Operating Environment
- Indoors or customer supplied NEMA-4 rated enclosure
Temperature
- 32° to 122°F (0° to 50°C)
Humidity
- 5% to 95% relative, non-condensing
Communications Ports
- TCP/IP – 10 or 100 Mbps
- SIA standard Wiegand/Clock-and-Data – two ports
Certifications
- UL 294 and UL 1076 Recognized Component for the US CSA 205 for Canada, FCC Class A Verification, EMC for Canada, EU (CE Mark), Australia (C-Tick Mark), New Zealand, Japan
Cable Distance
- TCP/IP – 300 feet (100 m) to next device using Category 5 cable, Alpha 9504C or 9405F
- Wiegand – 500 feet (150 m) to reader using ALPHA 1299C, 22AWG, 9-conductor, stranded, overall shield. (Fewer conductors needed if all control lines are not used)
- Input Circuits – 500 feet (150 m), 2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C (18AWG)
- Output Circuits – 500 feet (150 m), 2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG)
- Minimum wire gauge depends on cable length and current requirements.
Delta ACS – Access Controllers | ||
---|---|---|
Delta ACS Model | Description | Function |
V1000 | Access Controller | Host interface and access control processing for up to 32 door/reader interface (V100), input monitor (V200), or output control (V300) units. |
V100 | Door/Reader Interface (Connects to V1000) | Connects two access control card readers via Wiegand or Clock-and-Data interface controlling one or two doors. |
V200 | Input Monitor Interface (Connects to V1000) | Alarm input processing for up to 16 supervised input circuits, monitors and reports normal, off-normal, and tamper states. |
V300 | Output Control Interface (Connects to V1000) | Output control processing for up to 12 devices, contains 12 latching Form-C relays connecting up to 12 devices controllable by simple contact closures. |
V2000 | Reader Interface/Access Controller | Host interface and access control processing for two readers/doors. Ideal for small installations. |
Delta is committed to its policy of continual product and system improvement. Delta reserves the right, without obligation and without prior notice, to change product specifications and/or engineering design.