DA-V100
Two-Readers /One or Two Door Access Control Processing
Product Description
The DA-V100 Door /Reader Interface is a two-door access controller designed to connect most types of readers available in the market that uses wiegand or Clock-and-Data interface covering the range of card and biometric technologies. The DA-V100 can either be configured for two reader heads on two different doors with optional Exit devices or configured to provide an Entry/Exit configuration for In/Out control on a single door.
It provides wiring termination for reader heads, door sensors, exit devices and electro-locks for up to two doors. A maximum of 16 DA-V100 or mixed with other Delta Interface modules may be connected through one channel of high-speed RS-485 communication link to the DA-V1000 Network Controller. The network controller provides two RS-485 communication channels. The DA-V100 features on-board flash memory allowing program updates to be uploaded via the network when connected to a DA-V1000 controller. The network controller communicates with the system host via industry standard TCP/IP protocol over 10/100 Mbps Ethernet or the Internet. This architecture minimizes the impact on corporate LANs by using only one TCP/IP address for every 32 DA-V100 interfaces effectively controlling up to 64 doors and by handling low-level reader transactions on the RS-485 network.
Key Features
- Supports up to two configured
- Supports most reader heads using Wiegand or serial interface
- Reports supervised inputs status.
- Connects to the DA-V1000 via RS-485.
- Receives and processes real time commands from the DA-V1000.
- Reports all activity to the DA-V1000.
- Attractive polycarbonate enclosure protects components from damage.
- All connections and indicators are fully identified by silk-screened nomenclature on the cover.
- Processes off-line access control decisions based on facility code.
- UL294 and UL1076 recognized components.
Visual Indicators
- Communications LED flashes green for “transmit to host” and red for “receive from host.”
- Power LED indicates that sufficient DC voltage is being provided to the unit.
Easily Interfaced
- Quick-disconnect screw terminal connectors
- Rotary address switch (0-15)
- Inputs for:
- M2 readers
- 2 door monitor switches,
- 2 Request-to-Exit switches
- AC Fail Monitor*
- Battery Fail Monitor*
- Enclosure Tamper*
- *Can be configured as a general purpose input
Non-latching relay outputs (rated 2A@30VDC):
- 2 door strikes (configurable)
- 2 auxiliary devices: door held/forced alarm, alarm shunt, host off-line (comms down), or general purpose
Local Processing
- Alarm shunt and strike relay timing and latching functions
- Access control decisions based on facility code (degraded mode)
- Basic input/output linking
- LED/beeper control during card + PIN, scheduled unlock, and other transactions
Specification
Dimensions
- 5.8” W x 4.825” H x 1.275” D
- (147.32 mm x 122.55 mm x 32.38 mm)
Weight
- 12.4 oz (.35 kg)
Enclosure Material
- UL94 Polycarbonate
Power Supply Requirements
- 60 mA @ 9-18 VDC (with no readers connected) Recommended: Supervised linear power supply with battery backup, input surge protection, and AC fail and battery low contact outputs. When v100 is supplying power to readers the requirements are 600 mA @ 9-18 VDC. The V100 can supply 500 mA to two readers.
- Separate supervised DC supplies with battery back-up recommended for door locking or relay activated devices, or for HID MaxiProxR readers.
Operating Environment
- Indoors, or customer-supplied NEMA-4 rated enclosure
Temperature
- 32° to 122°F (0° to 50°C)
Humidity
- 5% to 95% relative humidity, non-condensing
Communications Ports
- RS-485 – two wire. Two SIA standard Wiegand/Clock-and-Data ports
Certifications
- UL 294 and UL 1076 Recognized Component for the US
- CSA 205 for Canada
- FCC Class A Verification
- EMC for Canada, EU (CE Mark), Australia (C-Tick Mark), New Zealand, Japan
- EN 50130-4 Access Control Systems Immunity for the EU (CE Mark)
Cable Distance
- RS485 – 4000 feet (1220 m) to host, using Belden 3105A, 22AWG twisted pair, shielded 100O cable
- Wiegand – 500 feet (150 m) to reader – using ALPHA 1299C 22AWG, 9-conductor, stranded, overall shield (Fewer conductors needed if all control lines are not used).
- Input Circuits – 500 feet (150 m), 2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C (18AWG)
- Output Circuits – 500 feet (150 m), 2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG)
- Minimum wire gauge depends on cable length and current requirements.
Delta is committed to its policy of continual product and system improvement. Delta reserves the right, without obligation and without prior notice, to change product specifications and/or engineering design.